VIEW FULL VERSION: Link
Title: Measurement Steps Of Round Enameled Wire
Tags: round enameled wire
Blog Entry: Common measuring tools for round enameled wire : micrometer and micrometer, precision O.002mm When the enameled round wire d is less than 0.100mm, the measuring force is 0.1~1.0N; when d ≥ 0.100mm, the measuring force is 1~8N; the measuring force of the enameled rectangular wire is 4-8N. When the nominal diameter of the conductor d ≤ 0.200mm, measure the outer diameter at 3 locations 1m apart, record 3 measured values, and take the average as the outer diameter. When the nominal diameter of the conductor d> 0.200mm, at two locations 1m apart, measure three times the outer diameter along the circumference of each location, record 6 measured values, and take the average value as the outer diameter. When the nominal diameter of the conductor d ≤ 0.200mm, please use any method that will not damage the conductor at 3 positions 1m apart to remove the insulating layer, and measure the conductor diameter at one time: take the average value as the conductor diameter. Like copper magnet wire , when the nominal diameter of the conductor d> O.200mm, please remove the insulating layer by any method that does not damage the conductor, measure three equal positions along the conductor circumference, and take the average of the three measured values as the conductor diameter.